1-800-375-7767
Ponca City, Oklahoma
Fast Nationwide Shipping
Return to Hayes Equipment Home Page
Return to Generator
Listings
Note: We have switched
from Generac to the Briggs and Stratton Industrial standby generators.
Click
here for our Briggs and Stratton Automatic Generator Page
Click Here for our main
generator page for portable generators in stock including Yamaha, Robin Subaru,
Kipor, Thunder, and More portable generators.
Generac Guardian Home or Office Residential and Commercial Stand By / Back
Up Emergency Power Generator Systems
Natural Gas or Propane (LP) Powered Complete Systems including Automatic
Transfer Switch, Wiring, and pad / slab.
|
|
 |
 |
The RESIDENTIAL EMERGENCY HOME STANDBY
emergency power generator is the most powerful, fully
automatic, enclosed generator of its size available anywhere. The
liquid-cooled models deliver up to 45,000 watts of backup electrical
power and the air-cooled models produce up to 15,000 watts. They are
quiet, reliable and loaded with special features.
UL-Listed Automatic Transfer Switch
- Automatically signals the generator to produce emergency
electrical power when utility fails and disconnects when utility
power returns.
- Within seconds your generator is producing electrical power
without you having to even flip a switch. You don't have to be
home for your system to work!
Automatic Exerciser
- Seven (7) day interval testing of the power generating system.
- You set the system to exercise at a prescribed time and day of
the week. This allows you to verify that your system is in peak
operating condition between utility failures.
Convenient Fuel Supply
- Operates on home/business natural gas or LP gas service.
- Provides you with potentially unlimited run time during
extended utility power failures.
- On Board LED System Fault Indicators - low oil pressure, high
engine temperature shutdown, overspeed/overcrank shutdown and
system ready light (air-cooled models only).
- Aids in performance of servicing in the event of a system
difficulty. Leads technician to a more specific area for
troubleshooting purposes. Reduces service time.
OHVI® Single or Twin-Cylinder Engine
- Full-pressure lubrication system with automotive spin-on oil
filter (air-cooled only).
- Finest lubrication technology available and provides
instantaneous disbursement of lubricant to all engine parts. Easy
change filter.
Automatic Voltage Regulator
- Maintains constant voltage with varying loads.
- Eliminates voltage spikes and allows operation of sensitive
electronic equipment.
Maintenance Friendly
- Air-cooled models include a hinged top and removable front
panel. Liquid-cooled models feature large removable enclosure
doors.
- Provides easy and quick access to all maintenance and service
parts. Reduces preventative maintenance or repair time.
|
|
|
|
|
 |
 |
- The completely automatic Guardian transfer switch monitors
incoming voltage from the utility line - around the clock.
- When utility power is interrupted, the automatic transfer switch
immediately senses the problem and signals the generator to start.
- The automatic transfer switch then safely closes off the utility
line and simultaneously opens a new power line from the generator.
- Within seconds, your Guardian generator system begins supplying
electricity to the critical emergency circuits of your home or
business. The transfer switch continues to monitor the utility line
conditions.
- When the automatic transfer switch senses the utility line voltage
has returned at a steady state, it re-transfers the electrical load
back to the utility line and resumes monitoring for subsequent utility
loss. The generator will continue to run for an engine cool-down
period of several minutes while the entire system stands ready for the
next power outage.
|
|
|
|
 |
 |
- Quiet, powerful Generac OHVI single-cylinder or V-Twin engines
fueled by natural gas or LP gas.
- UL Listed remote-mounted pre-wired automatic transfer switch with
8, 10 or 12 circuit emergency load center for fast and efficient
unattended transfer to generator when utility power fails.
- A standard weather protective enclosure with sound-absorbing
panels protects generator from harmful weather and also reduces
exterior noise levels. Includes key locks for security.
- Hinged top and removable front panel for easy serviceability.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser runs the system for twelve minutes
weekly to maintain top running condition.
- Installation system includes the pre-wired automatic transfer
switch with built-in load center, 30' and 2' wiring harnesses,
pre-wired external connection box, 1' flexible fuel line,
"Do-It-Yourself" installation guide and a composite mounting pad.
|
 |
|
 |
 |
 |
 |
 |
 |
Generator Set |
 |
 |
|
Model
Number |
04389 |
04456 |
04390 |
|
Rated Power LP (kW)* |
7 |
12 |
15** |
|
Rated Power NG (kW)* |
6 |
12 |
13 |
|
Voltage @ 60 Hz |
120/240 |
120/240 |
120/240 |
|
Phase |
Single |
Single |
Single |
|
Frequency |
60 Hz |
60 Hz |
60 Hz |
| Amps LP |
58.3/29.2 |
100.0/50.0 |
125.0/62.5 |
|
Amps NG |
50.0/25.0 |
100.0/50.0 |
108.3/54.2 |
|
Engine/Alternator RPM |
3600/3600 |
3600/3600 |
3600/3600 |
|
Engine |
410 cc.
14.5 HP
Generac OHVI
Single Cylinder |
992 cc.
30 HP
Generac OHVI
V-Twin |
992 cc.
30 HP
Generac OHVI
V-Twin |
| EPA/CARB
Certified |
Yes |
Yes |
Yes |
|
Fuel |
Natural Gas/
LP Vapor |
Natural Gas/
LP Vapor |
Natural Gas/
LP Vapor |
| Engine
Cooling |
Air |
Air |
Air |
|
UL2200 |
Yes |
Yes |
Yes |
| CUL
Listed |
Yes |
Yes |
Yes |
|
Main Line Circuit Breaker |
40 Amp |
50 Amp |
60 Amp |
|
Dimensions (L" x W" x H") |
48 x
24 x 28-1/4 |
48 x
24 x 28-1/4 |
48 x
24 x 28-1/4 |
|
Unit Wt. (lbs.) |
452 |
470 |
487 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
|
Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
|
Automatic Low Oil Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 72 Hz |
|
Overcrank Protection |
Standard |
|
Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
|
Engine Warmup |
10 seconds |
|
Engine Cool-Down |
1
minute |
|
Safety Fuse |
Standard |
|
Starter Lockout |
Starter cannot re-engage until 5 seconds after the engine has
stopped |
|
2 Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility failure/7 day exercise |
|
Off Switch |
Stops unit. Power is removed. Control and charger still operate |
|
Manual / test |
Start with starter control, unit stays on. If utility
fails,transfer to load takes place |
|
|
 |
 |
 |
 |
 |
 |
Transfer Switch |
 |
 |
| No.
of Poles |
2 |
|
Current Rating (amps) |
100 |
|
Voltage Rating (VAC) |
250 |
Utility Voltage Monitor (fixed)
Pick-up
Drop out |
80%
60% |
|
Return to Utility |
Approx. 13 seconds |
|
Exercises 7 minutes weekly |
Standard |
| UL
Listed |
Standard |
|
Dimensions (H" x W" x D") |
26.5 x 12.5 x 7 |
|
|
|
|
|
 |
 |
- Quiet, powerful, liquid-cooled engine fueled by natural gas or LP
gas.
- A standard weather protective enclosure protects generator from
harmful weather and also reduces exterior noise levels. Includes key
locks for security.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser runs the system for fifteen minutes
each week to maintain top running condition.
- Standard 100-amp remote-mounted automatic transfer switch for fast
and efficient unattended transfer to generator when utility source
fails
|
 |
|
 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
|
Start/Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
|
Automatic Low Oil Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 70 Hz |
|
Overcrank Protection |
Standard |
|
Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
|
Engine Warmup |
15 seconds |
|
Engine Cool-Down |
1
minute |
|
Safety Fuse |
Standard |
| |
|
|
Safety Fuse |
Standard |
|
Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has
stopped |
|
2 Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility failure/7 day exercise |
|
Off Switch |
Stops unit. Power is removed. Control and charger still operate |
|
Manual / Test |
Start with starter control, unit stays on. If utility fails,
transfer to load takes place |
|
|
 |
|
|
|
 |
 |
- Our quietest, liquid-cooled model.
- Powerful, industrial engine fueled by natural gas or LP gas.
- A sound attenuated enclosure protects generator from harmful
weather and reduces exterior noise levels. Includes key locks for
security.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser runs the system for fifteen minutes
each week to maintain top running condition.
- Standard 200-amp remote-mounted automatic transfer switch for fast
and efficient unattended transfer to generator when utility source
fails.
|
 |
|
 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
|
Start / Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
|
Automatic Low Oil Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 70 Hz |
|
Overcrank Protection |
Standard |
|
Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
|
Engine Warmup |
15 seconds |
|
Engine Cool-Down |
1
minute |
|
Safety Fuse |
Standard |
|
Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has
stopped |
|
2 Amp Timed Trickle Battery Charger |
Standard |
| Mode
Switch: Auto Switch |
Utility failure/7 day exerciser |
|
Auto Switch |
Utility failure/7 day exercise |
| Off
Switch |
Stops unit. Power is removed. Control and charger still operate |
|
Manual / Test |
Start with starter control, unit stays on. If utility fails,
transfer to load takes place |
|
|
|
|
|
 |
 |
- Quiet, powerful, liquid-cooled engine fueled by natural gas or LP.
- A standard weather protective enclosure protects generator from
harmful weather and also reduces exterior noise levels. Includes key
locks for security.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser runs the system for fifteen minutes
each week to maintain to running condition.
- Standard 200-amp remote-mounted automatic transfer switch for fast
and efficient unattended transfer to generator when utility source
fails.
|
 |
|
 |
|
|
 |
 |
 |
 |
 |
 |
Controls |
 |
 |
|
Start / Stop Control |
Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds
overcrank protection. |
|
Automatic Low Oil Shutdown |
Standard |
|
Overspeed Shutdown |
Standard, 70 Hz |
|
Overcrank Protection |
Standard |
|
Automatic Voltage Regulator with Over-Voltage Protection |
Standard |
|
Engine Warmup |
15 seconds |
|
Engine Cool-Down |
1
minute |
|
Safety Fuse |
Standard |
|
Starter Lockout |
Starter cannot re-engage until 5 seconds after engine has
stopped |
|
2 Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility failure/7 day exercise |
|
Off Switch |
Stops unit. Power is removed. Control and charger still operate |
|
Manual / Test |
Start with starter control, unit stays on. If utility fails,
transfer to load takes place |
|
|
|
WARRANTY
2 Year manufacturer's Limited Warranty.
2 Years / 2000 hours (whichever comes first) Parts and Labor.
Some restrictions apply. Call for more details or we can email you a .pdf
copy of the full warranty policy.
For More Information or to place an order call 1-800-375-7767
BACK TO GENERATOR LISTINGS
Copyright © 2001-2006 Hayes Equipment -
All Rights Reserved.